D‹‰®—¬Ší‚ð—p‚¢‚½‚Žü”gŽ¥ŠE‹¤–ÂŒ^–³ü“d—Í“`‘—ƒVƒXƒeƒ€‚É‚¨‚¯‚éÅ‘åŒø—¦’Ç]§Œä
Œ´—_Žu˜Y, ‘å—¢’CŠó, ŠÖ‰®‘å—Y
”¼“±‘Ì“d—͕ϊ·Œ¤‹†‰ï(SPC), July, 2018. [pdf document]

<Abstract>

This paper presents a design of the pre- and post-regulation magnetic-resonance WPT system with Class-D recti er. The class D recti er has no capacitance components in its operation, which can be expressed by only the equivalent resistance. This means that the reactance-component variations do not yields when the class-D recti er is applied to the receiver part of the pre- and post-regulation WPT systems. The experimental results show that the proposed system is effective for coil misalignments compared to the Class-E2 WPT systemD